If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. Master_Builder_800, GreekAnalyzer, adamich and 1 other person. Simply put you're "tunneling" up to 32 channels of information from one point to another. A hollow 5x5x5 cube of controllers can provide channels to hundreds of interfaces without a p2p. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule. Because the ME Controller has a limited surface area, therefore a limited number of channels, u/prozacgod came up with the idea of using a specific shape that has a large surface area that fulfils the maximum size of an ME Controller. 8 in normal cables. There is no theoretical limit to size, so long as the structure is no smaller than 3 blocks on any size (i. Nov 21, 2014. D:perTickNetworkBridge= the number of AE units required to power a Quantnum Network Bridge. 000,- if you set it up with only 64k units (no co unit, no crafting monitor). The ME Controller is a block added by Applied Energistics 2. But depending on the choosen balance between less or more effort the actual amount max might vary between values like 32, 128, 512 or 1024. r/feedthebeast. So in my picture you can kinda see a fluix cable running along the bottom of the controllers - this is attached to the controllers with quartz fiber (which allow AE2 power. Make a doughnut shaped controller multiblock with 8 controllers. Replace VERSION with the desired one. That means it can transfer 16krf/t. ME 컨트롤러는 이 채널 제한을 최대 32채널로 확 늘려버리는 블럭으로, 컨트롤러. ME Controller • ME Covered Cable. r/feedthebeast. It can be small or big, but only one per network. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. Notifications Fork 556; Star 1. 2 2.グラインドストーンを作る. The max channels the wireless connector can pass is 32, I believe you may be able to P2P more channels through it, but I haven't tried in a year. The controller is a multiblock structure that follows a few rules: It can be no bigger by 7x7x7; A controller block must not connect to more than 2 other controller blocks on the same axis, or else it will idle; There can only be 1 on the network, or both will idle. 0 [1. Der Mod der das möglich macht, nennt sich applied Energistics 2. The AE2 Stuff Network Visualisation Tool obviates the need for a mess of colored cables, too. AE2 rv3 beta6. All the autocrafting bits and bobs are still there and operational. Don`t. Join. It is the heart of ME Networks and is used to provide more channels to the network. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. Now its working to the maximum potential it has. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. Therefore it at first seems that the most efficient use of disk space would be to use 1k disks because the index would be as small as it could be. You shouldn't configure anything else on the storage bus. This configuration seems to allow me to have as much as 9408 channels and i know that i don't really need this many, but it's fun to reach the limits sometimes. Basic fluix cables have a maximum of 8 channels that can connect in a single branch. . My brother and I completed (up until Avaritia because mindless grind) Enigmatica 2 Expert with just 3 ME Controller blocks, and we had pretty much every machine set up for auto-crafting, and made recipes for. The p2p network by itself is a normal ME network (with the one difference that it connects p2p tunnels instead of storage/crafting devices etc. This structure can be built in any cuboid, or size as long as the following Criteria are met. Get to know AE2 in a new way! - Download the Minecraft Mod AE2 Additional Opportunity by Domaman202 on Modrinth. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. dman11235 is on the right track, but to expand a bit. 1. Jan 15, 2015. (6) some EnderIO energy conduits for the power supply (if you want to be compact - they can share the space with the item conduits)OMFG THXS I loved ae1 and was heart broken when ae1 didn't get updated to 1. Learn P2P Tunnels. You may be looking for ME Controller from Applied Energistics . None yet. Dense, P2P and Quantum Ring all support 32 channels. AE2 current setup. You can attach the storage bus to the bottom of the drawer controller. Join. Not too shabby. Configuration file (ae2ao. If you want to see if you can access your ssn from your ae2 you'll need everything above plus some ME cables and a storage bus. items in storage drawers and connect the controller to the ME network with a storage bus. Many Pattern Provider as you need to feed your recipes. ae2's energy/dense energy cells can be connected anywhere on me system and act a the system's battery. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). The ME Wireless Access Point is a block added by the Applied Energistics 2 mod. After making the room proper, I discovered that the drawer controller can control drawers that are 12 blocks away from the controller in any direction. Screenshots. I thought everything was fine. This is okay when dealing with busses, interfaces, and molecular assemblers. You can make that thing look like a tree, with p2ps holding 8 channels each everywhere. I then use an Ender IO power monitor to turn the reactor on and off. 12. 2. More than enough channels. Then a single stand of smart cable to wherever I'm working at. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. I've tried a few different ways to power the unit. Lazy AE2の導入方法. Key things to remember about channels: Each side of a controller block can support 32 channels. The Controller has the ability to transmit data throughout the ME Network using 32 channels per side. Each of these towers currently uses 28 channels - 22 interfaces and 6 Crafting CPUs. 1. Use multiple cells/drives. So within rule 2, there are 6 corner blocks (max 3 connections), 60. BUT I fear I might be out of channels one day, once I have so many ME Storage Buses. Welcome to the Applied Energistics Mod!This mod is all about digital storage and is much more complicated to it's counter part Refined Storage. The "flat controller blocks" are in reality Dense Transformers from the mod Immersive Cables (btw the mod is great, it gives so kuch freedom and clears a lot of wire around). 6 P2P MLG Pro . The blocks you see in my screenshots are the futura blocks you're talking about, but yea that's an idea, finally I just added a shape in the center of my room. Although the chest's storage capacity is limited to one Cell, it has it's purpose. 大容量チェストMODとして. As far as exceeding the 7-consecutive-controller-blocks restriction is concerned, I think its hard coded, although you CAN turn off channels in the config file (networkfeatures field) - if your goal is just to have more channels. There can be one controller on a network at most. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). When your networks starts to grow, so must your ME Controller. any rf/fe source can be used (either hooked up to the controller or an energy acceptor) Reply replyInscribers can go die in a fire. To get the full 32, you need to use DENSE me cable, which is kind of a pain to craft, but it will allow the full 32 channels to accessed. Use quartz to supply power and short-circuit the ME signal (force it to go through the p2p); just go around the p2p with quartz. But in Minecraft you need to. You only need 1 cable at the top of the 8 drives in each “block”. Now, dense cables are a bit expensive, so you probably don't want them to be wired all over your base. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. Featured playlist. 1. like it doesnt exist. One dense cable gives 32 channels, which is enough to autocraft 288 items (9 items per interface; molecular assemblers don't require a. . 3. Top: Double-compressed item Lower-left: Compressed item Lower-right: Base item Extracting is performed with the left mouse button. 10 now I'm trying to replicate my old setup without luck. com wrote: the existing config works, but i want that it only works with a me controller and the controller i cant find. Once it's in. malicious_bloke. Since the release of AE2, I've only kept basic networks (crafting terminal, controller, me drive, interfaces connected to machines). And so forth. It will either put the world into the cell or put the cell back into the world. You could have 32 Input P2P tunnels feed into one dense cable and then into one side of a Controller, and the output tunnels will be on the other side of the controller. 2. 4. Simply put, yes. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). Join. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. I then use an Ender IO power monitor to turn the reactor on and off. g. Interior: 135 Tunnels giving 4320 channels, 5 sides on the outside are required to extract these tunnels. So essentially whats happening, is the controller is changing its power state, this causes a neighbor update, this causes a mekanism cable to load and from the looks of of it; it then spirals outward loading your entire base or a least a pretty huge chunk of it; more then likely this then probably causes AE2 to get powered, then the chunks. For logistic pipes, you have xnet for automation, and you could rush integrated dynamics. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. Top 1% Rank by size . ME Controller • ME Covered Cable. It is still awesome. 1 1.クォーツを集める. Unknown. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). Already on version 1. When you exceed 8 devices, the network channel using the device turns off, you can remove the device or add a ME Controller. Part of a multi-block structure, used to digitally store the blocks within a certain space determined with the use of the Spatial Pylon. 2. Applied Energistics 2 (以下AE2)上級者を目指すためにいろいろとテストしてわかった他のMODにはないAE2独自の輸送特性についてのメモも含めた解説記事となります. Top 3% Rank by size. Controller Network - A network with a Controller. Adding a second would allow 128 more channels, I would say that's a pretty big step. クリスタル成長加速機. Any help appreciated. A pair of items which are used to establish a connection between network bridges. The crafting CPU as a multi-block only requires a single channel for the entire. Ae2 and drawers are compatible. r/feedthebeast. The ME Controller's texture will change to display the stored energy level for network use. • 18 days ago. In this episode of Applied Energistics 2, we review how Smart and Dense Cables connect and interact with devices. A Network requires power, which can be provided by various blocks, and may require ME. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. The me_interface provides the Common Network API and the following: getInterfaceConfiguration ( [slot:number]):table. When Ae2 blocks touch each other imagine there is an infinitely small cable connecting touching sides and that they behave like electrical wire. Each block has a placed or gap state, so 2 ^ 343 = 1. I'll tell you what are the differences between them, How to build a Hilber. If it's ok, cancel and double it, try again. More posts you may like. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. My Very First Quartz. The ME Controller is a multiblock structure, the minimum being 1x1x1 and the max being 7x7x7. 3. (note i don't have AE2 installed, so imagine the glass is an assembler and the iron is the interface) The ME Controller is the brain of your ME system. It has to be touching the drawer bank. . I have the same 5x5x5 controller working just fine on FTB Revelations as well so it isn’t a limitation that you’re running into. but thats buggy isnt it ? Theoretically the max size of a ME system depends on the number of faces of your controller you can access and extract channels from. The ME Controller is a block added by the Applied Energistics 2 mod. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. But you have to supply it with one of the following forms. The ME crafting terminal a great block to add to your ME network. Or you can connect separate energy acceptors to the sub networks. The only way to kick-start it seems to be breaking parts of the ME controller up and placing them back down. like it doesnt exist. 前提MODとして LibNine ・ Applied Energistics 2 を導入する。. You may be looking for ME Controller from Applied Energistics . I was partly going for wanting it to look a bit diff anyhow. Thanks for all your suggestions. Here's something that uses. Layers alternate ME interfaces connected to the dense cable, so each ME interface has access to 3 (top/bottom) or 4 assemblers. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Whenever you have more than 8 devices in a network, an ME Contr. If you need more than 8 channels, you need a ME Controller. it's probably because of nested recipes, calculations will take forever to calculate tier 1 essence -> tier 2 -> tier 3 -> tier 4 -> tier 5 -> tier 6 essences needed to craft each tier of seeds. I think that the most efficient controller possible doesn't have any loops- that is, the controller blocks form a long, perhaps branching, chain. The only ME Controller. i currently have 2 energy acceptors connected to the same glass cable, and the. Youd. If dyed, cables will not connect to ones of a different color, which makes it easier to have many networks close together. AppliedEnergistics / Applied-Energistics-2 Public. Quick note, sticking the Cell into a crafting grid when it has no Items stored as data will also work to extract the component. As the other comments say You’ve got too many cables connecting. P2P Tunnel or "Point to Point Tunnels" are a versatile configurable system to move items / redstone / power / and fluids from one location to another though an existing ME Network without storage. On Thu, Feb 18, 2016 at 3:13 PM TTLPcraft notifications@github. I like it as it's a challenge. 大容量チェストMODとして. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. AE2 ME Controller Keeps Flickering. Thats: 16 * 1024 * 1024 * 10 * 32 = 5'368'709'120 items per side of an ME controller. SSD can have as many of these ad-hoc networks as you want. I could basically make any object I wanted in the game. I've tried. The structure must be an ME network with a number of Spatial Pylons which define the target region. The island bridges were ~80% full. 3 sides total of 24 channels instead of using 4 sides using 4-6 channels. But it also means that they connect even if you don't want them to and you can get cross connections. This build is actually one of the oldest things in this save, made at around 80 hours played. 1 Definitions and conceptual implications . Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. 3 3.MEコントローラ、MEチェスト及びMEストレージセルを作る. 0:00 / 9:22. All Spatial Pylons must be either connected with cable or via a QNB, and on the same network. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. 1つの. Storing an item however always takes the same amount of space, regardless of the drive. Since AE2 is the only mod which uses AE, there isn't a good reason to make a 3rd party power converter to break it. Blocking mode for sub-networks point main network toward sub net for 1:1 or point sub networks toward the main interface for up to 5 sub networks per interface. Taking this to the max, you can add a Controller and use Dense Cables. Join. At the center of the tower is dense cable. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). The ME Controller is a block added by Applied Energistics and is the heart of ME Networks. Or just do the level emitter thing, or external automated crafters and pre. The 63 types is a non issue for me. one ME Access Terminal or ME Crafting Terminal if you have chosen an ME Drive as your first Storage. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. This means you can send one kind of power into machines never designed to work with it, which causes major balance issues. It also has its own power generator in the form of Vibration Chambers. Feed The Beast Wiki. Configure the interface. Every machine in AE2 takes up 1 channel. Almost right. One side of the me controller. ME P2P Tunnels allow for very dense cable connections using Applied Energistics 2 channels. 5. We have the ME Controller from applied energistics 2 for our minecraft mod tutorial. Crafting CPU. 2 Steve's First Network . Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. More than enough channels. An instant connection between any two points on an ME Network. 10) and remove a couple of potentially confusing commented-out lines: OpenComputers 1. Got 2 Mekanism ore quadrupling setups but they aren't running constantly. When taken by itself, the ME Controller does nothing. The ME Controller is a block added by Applied Energistics 2. Time to head for EMC a. Hallo,in diesen Video erfahrt ihr wie ihr ein eigenes Me-System bauen könnt. a few minutes ago, I got it to work. アイテムをデジタルデータ化して貯蔵、運用するといった趣のMOD。. I'm pretty sure I've seen people do wall of drives, which would mean <n> drives x 10 <disks x 63 <item types> * <average NBT size across all drives> space is needed. When I play AE2 I usually start off with a tiny Ad-hoc system (no Controller, just use an Energy Acceptor; you get 8 channels) just so I can start using the Crafting Terminal and power Crystal Growth Accelerators (switched on/off with a Toggle Bus), and then jump right to this kind of clearly overkill, 8-Main, 1-P2P Controller setup prior to. When you create a P2P into a dense cable, you are converting 32 channels from 1 facing into 1 channel. . This means you can output to as many points as you want, but only input at a single point per tunnel. Applied Energistics 2; Energy, Fluid, and Item Transport; Addons; Storage; Main File 1. If you’re having trouble executing the mod, try reading this article of ours that teaches mod implementation for Minecraft. I had the exact same chunk loading results. Yep, we finish the max size me controller, and get to the draconic staff of power and the philosopher's stone, just for good measure. wireless. It also includes some examples of how to use basic. 1kAE/t. modsフォルダの中に、ダウンロードした Lazy AE2 を jarファイルのまま コピー&貼り付けする. Manages a single auto crafting task from start to finsh, built of various crafting units. ago. If you want to do with with only AE2, then you are going to want to use sub-networks. Applied Energistics 2. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. Channels are a limiting factor on how big an AE network of devices can be. The size of the ME Controller must be within 7x7x7; else it will turn red. at least one Storage Block (ME Drive or ME Chest) The following are rather optional. . Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). Extreme ME Controller with 22 841 channels (Creative AE2 Build) Some time ago I got a request to build an ME Controller with maximum amount of channels possible. This device also requires a large amount of power to operate. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. . And so forth. Crafting CPU. 5 Some examples of sub-networks and their use . it can be hollow, but be careful, some of the outer ones will deactivate, you will have to add holes. Von den neuen R. P2P Tunnel. The 1k ME Storage Cell is the first tier of item storage added by Applied Energistics 2. The maximum size of the connected block ix 7x7x7 (343 blocks). I've read similar problems posted on this subreddit and. Theinventor10. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. On this particular map, only one meteor was found and we pregenerated a 3km radius map. or add the modCompileOnly line to your existing dependencies task to your build. furnace, puverisor, maga crusible) or onther not the CPU. The ME Controller's texture will change to display the stored energy level for network use. 12. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. Nope. ago. My understanding of the rules of Controllers that there can only be one set of controllers per network, the controller multiblock can be 7*7*7 at the largest, and all blocks must have at least 2 adjacent sides sides exposed. " Such networks are limited to only 8 Channels. Yes, an ME Interface can use 6 MAs at the same time without other augments. 適切に隣接させるとマルチブロックになる。. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. Obviously 6 sides/block would be optimal but that can only happen with a single block, so it's not scalable, similarly 5 sides/block can only happen with 2 blocks, so the best you can get is 4 sides/block, meaning each controller block is connected to at most 2 others, i. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. The AE2 wiki says, the ME Storage Bus needs its own channel. It is not possible to have 2 ME Controllers in one ME Network, though a multiblock structure can be created. ago. Most devices such as standard cables, and machines can only support up to 8 channels. wireless. This can be useful to move a multi-block stucture or a processing machine set-up. The item type cap is 61 *per drive*, so once you get 3-4 drives you're pretty much set. The current AE2 developer has said that he does not want the storage system to be a power provider. The drives will act a bit weird until you get all the tunnels configured with your memory card. Thats why you need the cells, they increase your Maximum rf storage, and therefore your maximum possible. Refined Storage vs Applied Energistics 2 for displaying a. The maximum amount of items a Storage Bus can work with reliable with full Capacity Upgrades is 63 different items. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). 1. 18. In AE2 the ME Interface is basically instantaneous, so it should be limited by whatever is pushing the items into it. Commonly used for Sub-Networks. . Top 1% Rank by size . You are correct. Seems weird that it wont try to take a different route that's the same length to the controller. when cheated it on online server or local/single player it acts like a 'stone block' its possible to edit it with the chisel and it becomes another block (like the chisel mod works) Minecraft Version: 1. 2; Forge; Nov 7, 2023;. I:max. In that setup each interface was adjacent to at least 3 assemblers, which was the max a Crafting CPU with no co-processors could utilize. The maximum size of the connected block ix 7x7x7 (343. Today we will. The mod includes a. In the case of AE2's assemblers, that's probably going to mean a controller, a single assembler block, a memory block, and a hard drive; but again, I'm guessing. The bus priority should be extremely high, set it to 10000 to be positive. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). Not connected to same dense cable. 432. Wiring has its own simple concepts that go along with this channel system: 0. AE2 itself adds Certus Quartz Crystal, and makes use of vanilla's Nether Quartz as well. 0:00 / 9:22. Also, AE2 uses priorities intelligently. My Very First Quartz. A basic ME Network starts with an ME Controller powered by a reliable energy source (EU RF or MJ) and an ME Drive or ME Chest with a Storage Cell inserted to be functional. The barrier to entry for AE2 is terrible. If an ae2 system is powered through an energy acceptor but has no controller it can support up to 8 channels. Feed The Beast Wiki. It's basically like taking a storage cell and limiting it to only hold one or 2 or how ever many, really different items. 3 Controlling the Network . That's 32x32 channels (1,024) going through a single dense cable line. 1. 7. Server address is sb. 2. Then a single stand of smart cable to wherever I'm working at. I have chunk loaders at my Jurassic park and my main base. Items like the Interface, Import Bus, ME Drive block, etc all consume 1 channel per device. AE2 Version: appliedenergistics2-rv6-stable-7. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. In this video I will give an example of a compact and very competent ME Controller design that can. . 7. If a controller remains red, one of the rules are broken and the controller is. The AE2 CPU doesn't need a frame, which means you can have a big, pretty array of them. Also worth noting that just a 1K fluid cell can hold over 8000 buckets of a fluid if its partioned. You specify the region and put in a Spatial Cell (2 16 or 128 and give the IO port a redstone signal. Place down the Storage Drawer, install the Void Upgrade, Lock the Drawer with the Item (or. The ME Controller was only really necessary for when there are channels. This setup provides 2304 channels (if I calculated it properly), so you can hook up 2304 different devices, such as furnaces or chests, or alloy smelters, sagmills, storage drawers, ME Drives (also part of AE2 - lets you store items digitally)There are two ways. Now your next recipe should be named item 1 + the next 8 components = named item 2. Then place your power generator adjacent to that.